Technical Article

What the A, B and C Finding Categories Actually Mean

Published: 2026-09-05 4 min read Reference: IMCA M190 Rev. 3 § 4.3 & IMCA DP Audit Guidance
Key Takeaways
  • Category A (Critical Finding): a single failure causes loss of position or breaches a safety barrier. Immediate rectification is required and DP critical operations are prohibited until it is closed out.
  • Category B (Serious Finding): reduced redundancy or a potential cascading-failure risk. Rectification within a defined deadline is permitted, supported by documented close-out evidence.
  • Category C (Observation & Suggestion): procedural or operational recommendations guiding preventive maintenance and system optimisation.

The List of Findings appended to every DP verification report is the section that charterers and class societies scrutinise most closely. Under the internationally recognised IMCA M190 standard, findings are divided strictly into three tiers — A, B and C — and each tier carries entirely different legal and commercial consequences:

Category A Findings (Critical / Fatal)

Definition: the DP redundancy principle is found to have been materially broken. Examples: loss of the main control supply to one thruster causing interlocked tripping of multiple thrusters across the vessel; a bus-tie section breaker failing to open reliably; or a single sensor failure causing the system to misoperate and drift.

Consequences and requirements: this item carries a veto. Until the root cause has been fully established and the physical repair completed, the vessel does not meet the compliance conditions for DP operations. After rectification the surveyor must re-attend to re-test, and the report must include a dedicated close-out record countersigned by the master as witness.

Category B Findings (General Deficiency / Rectification Within Deadline)

Definition: basic redundancy is retained, but a branch protection operates abnormally, UPS battery capacity test results are low, thrust feedback shows intermittent error, or calibration is overdue.

Requirements: a reasonable rectification grace period is normally allowed (for example 14 to 30 days). After the owner has replaced spares or retuned parameters, a close-out evidence pack — work orders, photographs and test parameters — must be provided, and the item may only be closed once confirmed by our reviewing surveyor.

Category C Findings (Observation and Suggestion)

Definition: not a direct breach of classification rules, but an improvement recommendation reflecting good marine practice. Examples: reinforcing cable tray labelling, advising on DP room air-conditioning filter cleanliness, standardising test record formats.

An Lai works on a “closed-loop management” principle: verification is not about finding fault and issuing a list. We have electrical and control engineers on staff who can carry out fault diagnosis and remediation for Category A and B findings directly for the owner, ensuring every item is closed out on a solid chain of evidence.

Prepared by the technical team of An Lai Ship Management (Shenzhen) Co., Ltd. for reference and discussion with owners, superintendents and masters.

For programme preparation or technical assessment on a specific vessel, please contact: marine@anlaiship.com